Showing 521-525 of 637 items.
Lab Name | Lab Type | Address | City | District | Active Lab Accreditation/Proficiency | Lab Status | Actions |
---|---|---|---|---|---|---|---|
Sequoia Consultants, Incorporated - PCC Trailer #3 | Private | 361 West Grove Avenue | Orange | 12 | CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) | Active | View |
Sequoia Consultants, Incorporated - PCC Trailer #4 | Private | 361 West Grove Avenue | Orange | 12 | CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) | Active | View |
Sequoia Consultants, Mobile Laboratory SR-99 | Private | 411 W Ave H-6 | Lancaster | 6 | CT 105: Calculations - Gradings (JTCP) CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 231: Relative Compaction - Nuclear Gage CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC CT 529: Proportions in PCC - Coarse Aggregates CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | Active | View |
Sequoia Valley Testing & Inspection | Private | 756 East Date Avenue | Porterville | 6 | (No active accredited test methods) | Expired | View |
SHN Eureka Laboratory | Private | 812 West Wabash Avenue | Eureka | 1 | CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 206: SpG & Absorption - Coarse Aggregates CT 207: SpG & Absorption - Fine Aggregates CT 208: Apparent SpG - Fine Aggregates CT 209: SpG for Soil CT 211: LA Rattler CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 231: Relative Compaction - Nuclear Gage CT 234: Uncompacted void - Fine Aggregates CT 235: Flat and Elongated Particles CT 304: Sample Preparation - HMA CT 308: Bulk SpG and Density - HMA CT 309: Max SpG and Density - HMA CT 366: Stabilometer CT 370: Moisture Content by Microwave CT 375: AC Density by Nuclear Gage CT 379: AC Content by Nuclear Gage CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | Active | View |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel