Search Technicians
Showing 1,001-1,005 of 3,023 items.
First Name | Last Name | Technician ID | Lab(s) | Active Certifications | Details |
---|---|---|---|---|---|
Triston | Netherton | 3712 | 1) Sierra Pacific Materials 45315 Lost Hills Road Coalinga District 6 2) SPM-Templeton 425 Vopli Ysabel Paso Robles District 5 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T166: Bulk SpG of Compacted HMA - SSD (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T269: Percent Air Voids - HMA (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) AASHTO T335: Percentage of Fracture (JTCP) CT 105: Calculations - Gradings (JTCP) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 306: Reducing Samples of Asphalt Mixtures (JTCP) | View |
Bradley | Van Hecke | 3714 | 1) Twining Laboratories of Southern California 3310 Airport Way Long Beach District 7 | CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA | View |
Michael | Clarke II | 3717 | 1) Structure Groups 2352 Research Drive Livermore District 4 | CT 125 AGG: Sampling - AGGREGATES CT 125 BIT: Sampling - BITUMINOUS CT 125 HMA: Sampling - HMA CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
Michael | Clary | 3719 | 1) Structure Groups 2352 Research Drive Livermore District 4 | CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
Shawn | Snowdale | 3721 | 1) Twining Laboratories of Southern California 3310 Airport Way Long Beach District 7 2) Twining Laboratories of Southern California 111 North Main Street, Unit A Riverside District 8 3) Twining, Incorporated - Long Beach, Mobile Laboratory 1 24300 Avenida De La Carlota Laguna Hills District 7 | CT 105: Calculations - Gradings (JTCP) CT 125 AGG: Sampling - AGGREGATES CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel