Search Technicians
Showing 1,246-1,250 of 6,765 items.
| First Name | Last Name | Technician ID | Lab(s) | All Certifications | Details |
|---|---|---|---|---|---|
| Gerardo | Portea | 2051 | (Not associated with any lab) | CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
| Michael | Padgett | 2052 | (Not associated with any lab) | (No certified test methods) | View |
| Jonathan | Arthur | 2053 | (Not associated with any lab) | (No certified test methods) | View |
| Joshua | De La Fuente | 2054 | 1) Vulcan Materials Company - Irwindale Laboratory 16009 East Foothill Boulevard Irwindale District 7 2) Vulcan Materials Company - Sun Valley 11401 Tuxford Avenue Sun Valley District 7 3) Vulcan Materials Company - Corona 1709 Sherborn Street Corona District 8 4) Vulcan Materials Company - Oro Grande Laboratory 20181 National Trails Highway Oro Grande District 8 5) Vulcan Materials Company - Palmdale 6851 East Avenue T Littlerock District 7 6) Vulcan Materials Company - Santa Ana Field Laboratory 1401 East Warner Avenue Santa Ana District 12 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) AASHTO T335: Percentage of Fracture (JTCP) ASTM D8225-19 (BMD ILS): IDEAL-CT ASTM D8360-22 (BMD ILS): IDEAL-RT ASTM WK86870 (BMD ILS): IDT-HT CT 105: Calculations - Gradings (JTCP) CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA (JTCP) CT 125 HMA: Sampling - HMA CT 306: Reducing Samples of Asphalt Mixtures (JTCP) | View |
| Hector | De La Torre | 2055 | (Not associated with any lab) | AASHTO T166: Bulk SpG of Compacted HMA - SSD (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T269: Percent Air Voids - HMA (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T283: Moisture Induced Damage (TSR) AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T312: Gyratory Compactor AASHTO T324: Hamburg Wheel-Track CT 105: Calculations - Gradings (JTCP) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 207: SpG & Absorption - Fine Aggregates CT 211: LA Rattler CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC | View |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel