Showing 161-165 of 637 items.
Lab Name | Lab Type | Address | City | District | Active Lab Accreditation/Proficiency | Lab Status | Actions |
---|---|---|---|---|---|---|---|
CT D05 - Buellton Construction | Caltrans | 400 South Highway 101 | Buellton | 5 | (No active accredited test methods) | Expired | View |
CT D05 - Carpinteria Field Laboratory | Caltrans | 3690 Santa Claus Lane | Carpinteria | 5 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) AASHTO T335: Percentage of Fracture (JTCP) CT 105: Calculations - Gradings (JTCP) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 231: Relative Compaction - Nuclear Gage CT 306: Reducing Samples of Asphalt Mixtures (JTCP) CT 308: Bulk SpG and Density - HMA CT 309: Max SpG and Density - HMA CT 375: AC Density by Nuclear Gage CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC CT 531: Core Length - PCC CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | Active | View |
CT D05 - Construction | Caltrans | (not set) | (not set) | 5 | (No active accredited test methods) | Expired | View |
CT D05 - Cuest Grade Construction | Caltrans | 1559 El Camino Real | San Luis Obispo | 5 | (No active accredited test methods) | Expired | View |
CT D05 - Materials Laboratory | Caltrans | 50 Higuera Street | San Luis Obispo | 5 | (No active accredited test methods) | Expired | View |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel