Showing 196-200 of 637 items.
Lab Name | Lab Type | Address | City | District | Active Lab Accreditation/Proficiency | Lab Status | Actions |
---|---|---|---|---|---|---|---|
CT D08 - Barstow Construction Acceptance | Caltrans | 1800 Dill Road | Barstow | 8 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 231: Relative Compaction - Nuclear Gage CT 308: Bulk SpG and Density - HMA CT 309: Max SpG and Density - HMA CT 370: Moisture Content by Microwave CT 375: AC Density by Nuclear Gage CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 552: Relative Compaction of Polymer Concrete CT 557: Temperature - PCC (JTCP) | Active | View |
CT D08 - Construction | Caltrans | (not set) | (not set) | 8 | (No active accredited test methods) | Expired | View |
CT D08 - Fontana Field Construction Laboratory | Caltrans | 13970 Victoria Street | Fontana | 8 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T248: Reducing Samples of Agg. (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 231: Relative Compaction - Nuclear Gage CT 308: Bulk SpG and Density - HMA CT 309: Max SpG and Density - HMA CT 370: Moisture Content by Microwave CT 375: AC Density by Nuclear Gage CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 552: Relative Compaction of Polymer Concrete CT 557: Temperature - PCC (JTCP) | Active | View |
CT D08 - Fontana Mobile Laboratory Trailer | Caltrans | 13970 Victoria Street | Fontana | 8 | (No active accredited test methods) | Expired | View |
CT D08 - Fontana Southern Regional Laboratory | Caltrans | 13970 Victoria Street | Fontana | 8 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO T30: Mechanical Analysis of Extracted Aggregate AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T84: SpG & Absorption - Fine Aggregates AASHTO T85: SpG & Absorption - Coarse Aggregates AASHTO T96: L.A. Rattler AASHTO T166: Bulk SpG of Compacted HMA - SSD (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T210: Aggregate Durability Index AASHTO T248: Reducing Samples of Agg. (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T269: Percent Air Voids - HMA (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T283: Moisture Induced Damage (TSR) AASHTO T304: Uncompacted Void - Fine Aggregate AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T312: Gyratory Compactor AASHTO T324: Hamburg Wheel-Track AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) AASHTO T335: Percentage of Fracture (JTCP) ASTM D4791: Flat and Elongated Particles CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 203: Test for Mechanical Analysis of Soils CT 204: LL, PL, PI CT 205: Percent Crushed Particles (JTCP) CT 206: SpG & Absorption - Coarse Aggregates CT 207: SpG & Absorption - Fine Aggregates CT 208: Apparent SpG - Fine Aggregates CT 209: SpG for Soil CT 211: LA Rattler CT 212: Unit Weight of Aggregates CT 213: Organic Impurities of PCC sand CT 214: Sodium Sulfate Soundness CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 234: Uncompacted void - Fine Aggregates CT 235: Flat and Elongated Particles CT 301: "R" Value CT 304: Sample Preparation - HMA CT 306: Reducing Samples of Asphalt Mixtures (JTCP) CT 308: Bulk SpG and Density - HMA CT 309: Max SpG and Density - HMA CT 342: Portable Skid Tester CT 360: Surface Abrasion CT 366: Stabilometer CT 367: OBC CT 368: OBC of OGAC CT 371: Moisture Induced Damage (TSR) CT 382: AC Content by Ignition Oven CT 387: Inertial Profilers CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 531: Core Length - PCC CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) CT 643: Resistivity and pH Measurements | Active | View |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel