Search Technicians
Showing 301-305 of 3,022 items.
First Name | Last Name | Technician ID | Lab(s) | Active Certifications | Details |
---|---|---|---|---|---|
Augusto | Rios | 1710 | 1) S2 Engineering, Incorporated 27075 Cabot Road, Suite 117 Laguna Hills District 12 2) S2 Engineering, Incorporated 25104 Rye Canyon Loop Valencia District 7 3) S2 Engineering, Inc. 2411 North Clancy Street, Building 6, Unit-D Visalia District 6 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T166: Bulk SpG of Compacted HMA - SSD (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T269: Percent Air Voids - HMA (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) AASHTO T335: Percentage of Fracture (JTCP) CT 105: Calculations - Gradings (JTCP) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 231: Relative Compaction - Nuclear Gage CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 524: Flexural Strength of Rapid Strength - PCC CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 541: Flow Cone CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
Francisco | Lopez | 1711 | 1) Coreslab Structure LA, Incorporated 150 West Placentia Avenue Perris District 8 | CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) | View |
Stephen | DeBolt | 1716 | 1) Earth Systems Pacific - Palmdale 1024 West Avenue, M-4 Palmdale District 7 2) Earth Systems Pacific - Ventura 5917 Olivas Park Drive, Suite F Ventura District 7 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T166: Bulk SpG of Compacted HMA - SSD (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T269: Percent Air Voids - HMA (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) AASHTO T335: Percentage of Fracture (JTCP) CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 204: LL, PL, PI CT 205: Percent Crushed Particles (JTCP) CT 209: SpG for Soil CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 306: Reducing Samples of Asphalt Mixtures (JTCP) CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 541: Flow Cone CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
Ronald | Hanson | 1722 | 1) Geo-Advantec, Incorporated 457 West Allen Avenue, Suite 113 San Dimas District 7 | CT 125 AGG: Sampling - AGGREGATES CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA | View |
John | Cromer | 1723 | 1) Geo-Advantec, Incorporated 457 West Allen Avenue, Suite 113 San Dimas District 7 | CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 204: LL, PL, PI CT 205: Percent Crushed Particles (JTCP) CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 308: Bulk SpG and Density - HMA CT 309: Max SpG and Density - HMA CT 375: AC Density by Nuclear Gage CT 382: AC Content by Ignition Oven CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) CT 643: Resistivity and pH Measurements | View |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel