Showing 316-320 of 637 items.
Lab Name | Lab Type | Address | City | District | Active Lab Accreditation/Proficiency | Lab Status | Actions |
---|---|---|---|---|---|---|---|
Granite Construction Bakersfield Laboratory | Private | 3005 James Road | Bakersfield | 6 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T84: SpG & Absorption - Fine Aggregates AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T210: Aggregate Durability Index AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T304: Uncompacted Void - Fine Aggregate AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) AASHTO T335: Percentage of Fracture (JTCP) ASTM D4791: Flat and Elongated Particles CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 AGG: Sampling - AGGREGATES CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 HMA: Sampling - HMA CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 207: SpG & Absorption - Fine Aggregates CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 231: Relative Compaction - Nuclear Gage CT 234: Uncompacted void - Fine Aggregates CT 235: Flat and Elongated Particles CT 309: Max SpG and Density - HMA CT 375: AC Density by Nuclear Gage CT 382: AC Content by Ignition Oven CT 384: Combined Grade for HMA using up to 25% RAP | Active | View |
Granite Construction Bishop Laboratory | Private | Five Bridges Road | Bishop | 9 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO T30: Mechanical Analysis of Extracted Aggregate AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T84: SpG & Absorption - Fine Aggregates AASHTO T85: SpG & Absorption - Coarse Aggregates AASHTO T96: L.A. Rattler AASHTO T166: Bulk SpG of Compacted HMA - SSD (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T269: Percent Air Voids - HMA (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T304: Uncompacted Void - Fine Aggregate AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T312: Gyratory Compactor AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) AASHTO T335: Percentage of Fracture (JTCP) ASTM D4791: Flat and Elongated Particles ASTM D7741: AR Field Viscosity CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 AGG: Sampling - AGGREGATES CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 206: SpG & Absorption - Coarse Aggregates CT 207: SpG & Absorption - Fine Aggregates CT 208: Apparent SpG - Fine Aggregates CT 211: LA Rattler CT 212: Unit Weight of Aggregates CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 234: Uncompacted void - Fine Aggregates CT 235: Flat and Elongated Particles CT 304: Sample Preparation - HMA CT 306: Reducing Samples of Asphalt Mixtures (JTCP) CT 308: Bulk SpG and Density - HMA CT 309: Max SpG and Density - HMA CT 367: OBC CT 370: Moisture Content by Microwave CT 382: AC Content by Ignition Oven CT 384: Combined Grade for HMA using up to 25% RAP CT 385 RHMA: Crumb Rubber Modifier (CRM) | Active | View |
Granite Construction Company - DC-AC | Private | 35100 Dillon Road | Desert Hot Springs | 8 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T248: Reducing Samples of Agg. (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) CT 105: Calculations - Gradings (JTCP) CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 304: Sample Preparation - HMA CT 309: Max SpG and Density - HMA CT 370: Moisture Content by Microwave CT 382: AC Content by Ignition Oven | Active | View |
Granite Construction Company - Main Laboratory | Private | 38000 Monroe Street | Indio | 8 | (No active accredited test methods) | Expired | View |
Granite Construction Company (Big Rock) | Private | 34809 155th Street East | Llano | 7 | AASHTO T85: SpG & Absorption - Coarse Aggregates AASHTO T96: L.A. Rattler CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 206: SpG & Absorption - Coarse Aggregates CT 207: SpG & Absorption - Fine Aggregates CT 211: LA Rattler CT 212: Unit Weight of Aggregates CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 234: Uncompacted void - Fine Aggregates CT 235: Flat and Elongated Particles CT 308: Bulk SpG and Density - HMA CT 309: Max SpG and Density - HMA CT 370: Moisture Content by Microwave CT 382: AC Content by Ignition Oven | Active | View |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel