Search Technicians
Showing 396-400 of 3,021 items.
First Name | Last Name | Technician ID | Lab(s) | Active Certifications | Details |
---|---|---|---|---|---|
Andrew | Uribe | 1987 | 1) G3 Quality, Incorporated - Mobile Laboratory #1 25837 Business Center Dr. Suite F Redlands District 8 2) G3 Quality, Incorporated 13850 Cerritos Corporate Drive, Unit E Cerritos District 7 3) G3 Quality, Incorporated - Redlands Laboratory 25837 Business Center Drive, Suite F Redlands District 8 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T84: SpG & Absorption - Fine Aggregates AASHTO T85: SpG & Absorption - Coarse Aggregates AASHTO T96: L.A. Rattler AASHTO T166: Bulk SpG of Compacted HMA - SSD (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T210: Aggregate Durability Index AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T269: Percent Air Voids - HMA (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T283: Moisture Induced Damage (TSR) AASHTO T304: Uncompacted Void - Fine Aggregate AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T312: Gyratory Compactor AASHTO T324: Hamburg Wheel-Track AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) AASHTO T335: Percentage of Fracture (JTCP) ASTM D4791: Flat and Elongated Particles CT 105: Calculations - Gradings (JTCP) CT 106: Definitions - Specific Gravity (SpG) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 205: Percent Crushed Particles (JTCP) CT 206: SpG & Absorption - Coarse Aggregates CT 207: SpG & Absorption - Fine Aggregates CT 211: LA Rattler CT 216: Relative Compaction - Soils and Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 229: Durability (JTCP) CT 234: Uncompacted void - Fine Aggregates CT 235: Flat and Elongated Particles CT 306: Reducing Samples of Asphalt Mixtures (JTCP) CT 308: Bulk SpG and Density - HMA CT 309: Max SpG and Density - HMA CT 382: AC Content by Ignition Oven CT 384: Combined Grade for HMA using up to 25% RAP CT 389: Hamburg Wheel-Track CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC | View |
Derek | Bezotte | 1989 | 1) Sequoia Consultants, Incorporated 361 West Grove Avenue Orange District 12 | CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA CT 231: Relative Compaction - Nuclear Gage CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231) CT 521.1: Compressive Strength - PCC (ASTM C39 / C617) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 524: Flexural Strength of Rapid Strength - PCC CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
Isidro | Buenrostro | 1990 | 1) The Quality Firm 177 University Parkway Pomona District 7 | CT 125 ADMIX: Sampling - ADMIXTURE CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA CT 231: Relative Compaction - Nuclear Gage CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
Jennifer | Moore | 1991 | 1) RMA Group Carson 1210 East 223rd Street, Suite 319 Carson District 7 2) RMA Group - Main Laboratory 12130 Santa Margarita Court Rancho Cucamonga District 8 3) RMA Group - PCC #7 12130 Santa Margarita Court Rancho Cucamonga District 8 4) RMA Group - PCC #1 12130 Santa Margarita Court Rancho Cucamonga District 8 5) RMA Group - PCC#2 12130 Santa Margarita Court Rancho Cucamonga District 8 6) RMA Corona 25225 Maitri Road Corona District 8 7) RMA Group 6976 Convoy Court San Diego District 11 | CT 125 ADMIX: Sampling - ADMIXTURE CT 125 AGG: Sampling - AGGREGATES CT 125 BIT: Sampling - BITUMINOUS CT 125 CEM: Sampling - CEM CT 125 GEN: Sampling - GENERAL CT 125 HMA: Sampling - HMA CT 231: Relative Compaction - Nuclear Gage CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 533: Ball Penetration - PCC CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
Louis | Riley | 1992 | 1) RMA Group Carson 1210 East 223rd Street, Suite 319 Carson District 7 2) RMA Group - Main Laboratory 12130 Santa Margarita Court Rancho Cucamonga District 8 3) RMA Group -at All American Asphalt Corona 1776 All American Way Corona District 8 4) RMA Group - PCC #7 12130 Santa Margarita Court Rancho Cucamonga District 8 5) RMA Group - PCC #1 12130 Santa Margarita Court Rancho Cucamonga District 8 6) RMA Group - PCC#2 12130 Santa Margarita Court Rancho Cucamonga District 8 7) RMA Corona 25225 Maitri Road Corona District 8 8) RMA Group 10671 Jeffrey Road Irvine District 12 9) RMA Group 15505 East Lincoln Avenue Orange District 12 10) RMA Mobile Laboratory #11 12130 Santa Margarita Court Rancho Cucamonga District 8 11) RMA Mobile Laboratory #12 12130 Santa Margarita Court Rancho Cucamonga District 8 12) RMA Ehrenberg HMA Mobile Cibola Road Ehrenberg District 8 | AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP) AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP) AASHTO R47: Reducing Samples of HMA (JTCP) AASHTO R76: Reducing Samples of Agg (JTCP) AASHTO T166: Bulk SpG of Compacted HMA - SSD (JTCP) AASHTO T176: Sand Equivalent (JTCP) AASHTO T209: Max SpG and Density - HMA (JTCP) AASHTO T255: Evaporable Moisture Content (JTCP) AASHTO T269: Percent Air Voids - HMA (JTCP) AASHTO T275: Bulk SpG - HMA (JTCP) AASHTO T308: AC Content (Ignition Oven) - HMA (JTCP) AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP) CT 105: Calculations - Gradings (JTCP) CT 125 AGG: Sampling - AGGREGATES (JTCP) CT 125 HMA: Sampling - HMA (JTCP) CT 201: Sample Preparation - Soil and Aggregates (JTCP) CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP) CT 217: Sand Equivalent (JTCP) CT 226: Moisture Content - Soils and Aggregates (JTCP) CT 227: Cleanness Value (JTCP) CT 504: Air Content of PCC - Pressure Method (JTCP) CT 518: Unit Weight - PCC (JTCP) CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP) CT 523.2 Section B.3: Flexural Strength (Lab Test) CT 539: Sampling Fresh Concrete (JTCP) CT 540: Making Cylinders - PCC (JTCP) CT 543: Air Content of PCC - Volumetric Method (JTCP) CT 556: Slump - PCC (JTCP) CT 557: Temperature - PCC (JTCP) | View |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel