Lab details for CT D07 - Valencia Field Laboratory

Basic Information

Lab NameCT D07 - Valencia Field Laboratory
Manager NameJohn Dong
Lab EmailJohn.Dong@dot.ca.gov
Lab Telephone213-798-5952
Lab Fax562-926-1409
Lab Full Address25061 West Avenue Stanford, Suite 70, Valencia, CA 91355
Zip91355
Lab TypeCaltrans
District7
Mobile Lab Full Address, ,
Download TL-0113

RSP Information

13230 Firestone Boulevard, Suite G, Santa Fe Springs, CA 90671

Test Methods

California Test (CT) Accreditations

AASHTO/ASTM Proficiencies

Total 5 items.
Test MethodObtained DateExpiration DateStatusIA ResponsibleTechnician Certified?
AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP)2024-04-262025-04-26ActiveJay HortonYes
AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP)2024-04-262025-04-26ActiveJay HortonYes
AASHTO R76: Reducing Samples of Agg (JTCP)2024-04-262025-04-26ActiveJay HortonYes
AASHTO T176: Sand Equivalent (JTCP)2024-04-262025-04-26ActiveJay HortonYes
AASHTO T255: Evaporable Moisture Content (JTCP)2024-04-262025-04-26ActiveJay HortonYes

Technicians in the Lab

Technician Summary

Total 2 items.
First NameLast NameActions
KevinHopkins View
AvoKarajian View

Technician Details

Details for Kevin Hopkins

First NameKevin
Last NameHopkins
StatusActive
Total 15 items.
Certified California Tests(CT)
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
CT 105: Calculations - Gradings (JTCP)2024-06-142027-06-14ActiveBrian EllisYes
CT 125 ADMIX: Sampling - ADMIXTURE2016-06-192018-07-22ExpiredMajid FahrtoshYes
CT 125 AGG: Sampling - AGGREGATES (JTCP)2024-06-142027-06-14ActiveBrian EllisYes
CT 125 BIT: Sampling - BITUMINOUS2016-06-192018-07-22ExpiredMajid FahrtoshYes
CT 125 CEM: Sampling - CEM2016-06-192018-07-22ExpiredMajid FahrtoshYes
CT 125 GEN: Sampling - GENERAL2016-06-192018-07-22ExpiredMajid FahrtoshYes
CT 125 HMA: Sampling - HMA (JTCP)2024-06-072027-06-07ActiveGabriela LopezYes
CT 201: Sample Preparation - Soil and Aggregates (JTCP)2024-06-142027-06-14ActiveBrian EllisYes
CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP)2024-06-142027-06-14ActiveBrian EllisYes
CT 205: Percent Crushed Particles (JTCP)2018-07-132021-07-13ExpiredRichard HibbardNo
CT 216: Relative Compaction - Soils and Aggregates (JTCP)2018-07-132021-07-13ExpiredRichard HibbardNo
CT 217: Sand Equivalent (JTCP)2024-06-142027-06-14ActiveBrian EllisYes
CT 226: Moisture Content - Soils and Aggregates (JTCP)2024-06-142027-06-14ActiveBrian EllisYes
CT 227: Cleanness Value (JTCP)2024-06-142027-06-14ActiveBrian EllisYes
CT 229: Durability (JTCP)2018-07-132021-07-13ExpiredRichard HibbardNo
Total 9 items.
AASHTO/ASTM Proficiencies
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP)2024-06-072027-06-07ActiveGabriela LopezYes
AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP)2024-06-072027-06-07ActiveGabriela LopezYes
AASHTO R47: Reducing Samples of HMA (JTCP)2018-06-152021-06-15ExpiredBiplab BhattacharyaNo
AASHTO R76: Reducing Samples of Agg (JTCP)2024-06-072027-06-07ActiveGabriela LopezYes
AASHTO T176: Sand Equivalent (JTCP)2024-06-072027-06-07ActiveGabriela LopezYes
AASHTO T248: Reducing Samples of Agg. (JTCP)2018-06-152021-06-15ExpiredBiplab BhattacharyaNo
AASHTO T255: Evaporable Moisture Content (JTCP)2024-06-072027-06-07ActiveGabriela LopezYes
AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP)2024-06-072027-06-07ActiveGabriela LopezNo
AASHTO T335: Percentage of Fracture (JTCP)2018-06-152021-06-15ExpiredBiplab BhattacharyaNo

Details for Avo Karajian

First NameAvo
Last NameKarajian
StatusActive
Total 28 items.
Certified California Tests(CT)
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
CT 105: Calculations - Gradings (JTCP)2024-07-262027-07-26ActiveBrian EllisYes
CT 125 ADMIX: Sampling - ADMIXTURE2018-06-252019-06-25ExpiredMajid FahrtoshYes
CT 125 AGG: Sampling - AGGREGATES (JTCP)2025-02-212028-02-21ActiveGabriela LopezYes
CT 125 BIT: Sampling - BITUMINOUS2018-06-252019-06-25ExpiredMajid FahrtoshYes
CT 125 CEM: Sampling - CEM2018-06-252019-06-25ExpiredMajid FahrtoshYes
CT 125 GEN: Sampling - GENERAL2018-06-252019-06-25ExpiredMajid FahrtoshYes
CT 125 HMA: Sampling - HMA (JTCP)2025-02-212028-02-21ActiveGabriela LopezYes
CT 201: Sample Preparation - Soil and Aggregates (JTCP)2024-07-262027-07-26ActiveBrian EllisYes
CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP)2024-07-262027-07-26ActiveBrian EllisYes
CT 205: Percent Crushed Particles (JTCP)2024-07-262027-07-26ActiveBrian EllisNo
CT 216: Relative Compaction - Soils and Aggregates (JTCP)2024-07-262027-07-26ActiveBrian EllisNo
CT 217: Sand Equivalent (JTCP)2024-07-262027-07-26ActiveBrian EllisYes
CT 226: Moisture Content - Soils and Aggregates (JTCP)2024-07-262027-07-26ActiveBrian EllisYes
CT 227: Cleanness Value (JTCP)2024-07-262027-07-26ActiveBrian EllisYes
CT 229: Durability (JTCP)2024-07-262027-07-26ActiveBrian EllisNo
CT 231: Relative Compaction - Nuclear Gage2021-07-142022-07-14ExpiredMajid FahrtoshNo
CT 306: Reducing Samples of Asphalt Mixtures (JTCP)2025-02-212028-02-21ActiveGabriela LopezNo
CT 504: Air Content of PCC - Pressure Method (JTCP)2017-11-112022-11-11ExpiredBiplab BhattacharyaNo
CT 518: Unit Weight - PCC (JTCP)2017-11-112022-11-11ExpiredBiplab BhattacharyaNo
CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP)2020-06-172022-06-17ExpiredMajid FahrtoshNo
CT 523.2 Section B.3: Flexural Strength (Lab Test)2020-06-172022-06-17ExpiredMajid FahrtoshNo
CT 524: Flexural Strength of Rapid Strength - PCC2020-06-172022-06-17ExpiredMajid FahrtoshNo
CT 533: Ball Penetration - PCC2020-06-172022-06-17ExpiredMajid FahrtoshNo
CT 539: Sampling Fresh Concrete (JTCP)2017-11-112022-11-11ExpiredBiplab BhattacharyaNo
CT 540: Making Cylinders - PCC (JTCP)2017-11-112022-11-11ExpiredBiplab BhattacharyaNo
CT 543: Air Content of PCC - Volumetric Method (JTCP)2017-11-112022-11-11ExpiredBiplab BhattacharyaNo
CT 556: Slump - PCC (JTCP)2017-11-112022-11-11ExpiredBiplab BhattacharyaNo
CT 557: Temperature - PCC (JTCP)2017-11-112022-11-11ExpiredBiplab BhattacharyaNo
Total 9 items.
AASHTO/ASTM Proficiencies
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
AASHTO T11: Sieve Analysis (Washing) - Fine Aggregates (JTCP)2025-02-212028-02-21ActiveGabriela LopezYes
AASHTO T27: Sieve Analysis - Fine and Coarse Aggregates (JTCP)2025-02-212028-02-21ActiveGabriela LopezYes
AASHTO T30: Mechanical Analysis of Extracted Aggregate (JTCP)2025-02-212028-02-21ActiveGabriela LopezNo
AASHTO R47: Reducing Samples of HMA (JTCP)2025-02-212028-02-21ActiveGabriela LopezNo
AASHTO R76: Reducing Samples of Agg (JTCP)2025-02-212028-02-21ActiveGabriela LopezYes
AASHTO T176: Sand Equivalent (JTCP)2025-02-212028-02-21ActiveGabriela LopezYes
AASHTO T255: Evaporable Moisture Content (JTCP)2025-02-212028-02-21ActiveGabriela LopezYes
AASHTO T329: Moisture Content (Oven Method) - HMA (JTCP)2025-02-212028-02-21ActiveGabriela LopezNo
AASHTO T335: Percentage of Fracture (JTCP)2025-02-212028-02-21ActiveMajid FahrtoshNo