Lab details for CTU Precast

Basic Information

Lab NameCTU Precast
Manager NameEd La Fazia
Lab Emailed@ctuprecast.com
Lab Telephone530-749-6501
Lab Fax
Lab Full Address1260 Furneaux Road, Olivehurst, CA 95961
Zip95961
Lab TypePrivate
District3

RSP Information

1260 Furneaux Road, Olivehurst, CA 95961

Test Methods

California Test (CT) Accreditations

AASHTO/ASTM Proficiencies

Test MethodObtained DateExpiration DateStatusIA ResponsibleTester Certified?
No results found.

Testers in the Lab

Tester Summary

Total 4 items.
First NameLast NameActions
MajeedNoori View
RaymondWynn View
EdwardLa Fazia View
ChrisKerby View

Tester Details

Details for Majeed Noori

First NameMajeed
Last NameNoori
StatusActive
Total 17 items.
Certified California Tests(CT)
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
CT 105: Calculations - Gradings (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalNo
CT 125 AGG: Sampling - AGGREGATES (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalNo
CT 201: Sample Preparation - Soil and Aggregates (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalYes
CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalYes
CT 205: Percent Crushed Particles (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalNo
CT 216: Relative Compaction - Soils and Aggregates (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalNo
CT 217: Sand Equivalent (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalYes
CT 226: Moisture Content - Soils and Aggregates (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalYes
CT 227: Cleanness Value (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalNo
CT 229: Durability (JTCP)2020-10-302023-10-30ActiveSarbjit GrewalNo
CT 504: Air Content of PCC - Pressure Method (JTCP)2020-03-142025-03-14ActiveSarbjit GrewalYes
CT 518: Unit Weight - PCC (JTCP)2020-03-142025-03-14ActiveSarbjit GrewalYes
CT 539: Sampling Fresh Concrete (JTCP)2020-03-142025-03-14ActiveSarbjit GrewalYes
CT 540: Making Cylinders - PCC (JTCP)2020-03-142025-03-14ActiveSarbjit GrewalYes
CT 543: Air Content of PCC - Volumetric Method (JTCP)2020-03-142025-03-14ActiveSarbjit GrewalNo
CT 556: Slump - PCC (JTCP)2020-03-142025-03-14ActiveSarbjit GrewalYes
CT 557: Temperature - PCC (JTCP)2020-03-142025-03-14ActiveSarbjit GrewalYes
AASHTO/ASTM Proficiencies
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
No results found.

Details for Raymond Wynn

First NameRaymond
Last NameWynn
StatusActive
Certified California Tests(CT)
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
No results found.
AASHTO/ASTM Proficiencies
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
No results found.

Details for Edward La Fazia

First NameEdward
Last NameLa Fazia
StatusActive
Certified California Tests(CT)
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
No results found.
AASHTO/ASTM Proficiencies
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
No results found.

Details for Chris Kerby

First NameChris
Last NameKerby
StatusActive
Certified California Tests(CT)
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
No results found.
AASHTO/ASTM Proficiencies
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
No results found.