SIAD: Certificates for Jason Philpot
UNOFFICIAL COPY
Certificates for Jason Philpot
Basic Information
First Name | Jason |
---|---|
Last Name | Philpot |
Status | Active |
Associated Labs
Total 1 item.
Lab Name | Manager Name | Full Address | District | Page Alias |
---|---|---|---|---|
EnGEN Corporation | Wayne Baimbridge | 41625 Enterprise Circle South, Temecula, CA 92590 | 8 | Lab 1 |
Test Methods
California Test (CT) Certifications
Total 22 items.
Test Method | Expiration Date | Status | IA Responsible | Within Lab(s) Scope | Comments |
---|---|---|---|---|---|
CT 105 Calculations - Gradings (JTCP - HMA I / S&A) | 2022-05-24 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
CT 125 AGG Sampling - AGGREGATES (JTCP - HMA I / S&A) | 2022-05-24 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
CT 201 Sample Preparation - Soil and Aggregates (JTCP - S&A) | 2022-05-24 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
CT 202 Sieve analysis - Fine and Coarse Aggregates (JTCP - S&A) | 2022-05-24 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
CT 205 Percent Crushed Particles (JTCP - S&A) | 2022-05-24 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
CT 216 Relative Compaction - Soils and Aggregates (JTCP - S&A) | 2022-05-24 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
CT 217 Sand Equivalent (JTCP - S&A) | 2022-05-24 | Expired | Robby Rodriguez | Lab 1 | suspending until SE equipment can be verified. he was performing CSP and lab was 60F and SE shaker was not working correctly. Timer set for 45 seconds was actually 65 seconds. |
CT 226 Moisture Content - Soils and Aggregates (JTCP - S&A) | 2022-05-24 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
CT 227 Cleanness Value (JTCP - S&A) | 2022-05-24 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
CT 229 Durability (JTCP - S&A) | 2022-05-24 | Expired | Robby Rodriguez | Lab 1 | (No comments) |
CT 231 Relative Compaction - Nuclear Gage | 2020-06-14 | Expired | Seree Yenjai | Lab 1 | (No comments) |
CT 301 "R" Value | 2021-01-10 | Expired | Afsaneh Ostovar | Lab 1 | (No comments) |
CT 375 AC Density by Nuclear Gage | 2020-06-14 | Expired | Seree Yenjai | Lab 1 | (No comments) |
CT 504 Air Content of PCC - Pressure Method (JTCP - PCC) | 2021-12-10 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
CT 518 Unit Weight - PCC (JTCP - PCC) | 2021-12-10 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
CT 521.2 Compressive Strength - PCC (ASTM C39 / C1231) | 2019-07-13 | Expired | Afsaneh Ostovar | (No lab) | Created based on CT521 certificate ID49627 |
CT 521.1 Compressive Strength - PCC (ASTM C39 / C617) | 2019-07-13 | Expired | Afsaneh Ostovar | (No lab) | Created based on CT521 certificate ID49627 |
CT 539 Sampling Fresh Concrete (JTCP - PCC) | 2021-12-10 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
CT 540 Making Cylinders - PCC (JTCP - PCC) | 2021-12-10 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
CT 543 Air Content of PCC - Volumetric Method (JTCP - PCC) | 2021-12-10 | Expired | Sarbjit Grewal | (No lab) | (No comments) |
CT 556 Slump - PCC (JTCP - PCC) | 2021-12-10 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
CT 557 Temperature - PCC (JTCP - PCC) | 2021-12-10 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
AASHTO/ASTM Proficiencies
Test Method | Expiration Date | Status | IA Responsible | Within Lab(s) Scope | Comments |
---|---|---|---|---|---|
No results found. |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel