SIAD: Certificates for Joel D'Asaro
UNOFFICIAL COPY
Certificates for Joel D'Asaro
Basic Information
First Name | Joel |
---|---|
Last Name | D'Asaro |
Status | Active |
Associated Labs
Total 3 items.
Lab Name | Manager Name | Full Address | District | Page Alias |
---|---|---|---|---|
Sequoia Consultants, Incorporated | Ruben Jimenez | 361 West Grove Avenue, Orange, CA 92865 | 12 | Lab 1 |
Sequoia Consultants | Ruben Jimenez | 8295 Aero Place, Unit 320, San Diego, CA 92123 | 11 | Lab 2 |
Sequoia Consultants, Incorporated | Ruben Jimenez | 3403 West El Segundo Boulevard, Hawthorne, CA 90250 | 7 | Lab 3 |
Test Methods
California Test (CT) Certifications
Total 21 items.
Test Method | Expiration Date | Status | IA Responsible | Within Lab(s) Scope | Comments |
---|---|---|---|---|---|
CT 105 Calculations - Gradings (JTCP - HMA I / S&A) | 2025-09-16 | Active | Brian Ellis | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 125 AGG Sampling - AGGREGATES (JTCP - HMA I / S&A) | 2025-09-16 | Active | Brian Ellis | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 125 GEN Sampling - GENERAL | 2027-01-17 | Active | Edwin Rojas Flores | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 125 HMA Sampling - HMA (JTCP - HMA I) | 2022-09-13 | Expired | Sarbjit Grewal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 201 Sample Preparation - Soil and Aggregates (JTCP - S&A) | 2025-09-16 | Active | Brian Ellis | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 202 Sieve analysis - Fine and Coarse Aggregates (JTCP - S&A) | 2025-09-16 | Active | Brian Ellis | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 205 Percent Crushed Particles (JTCP - S&A) | 2025-09-16 | Active | Brian Ellis | Lab 1, Lab 2 | (No comments) |
CT 216 Relative Compaction - Soils and Aggregates (JTCP - S&A) | 2025-09-16 | Active | Brian Ellis | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 217 Sand Equivalent (JTCP - S&A) | 2025-09-16 | Active | Ashley Shaw | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 226 Moisture Content - Soils and Aggregates (JTCP - S&A) | 2025-09-16 | Active | Brian Ellis | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 227 Cleanness Value (JTCP - S&A) | 2025-09-16 | Active | Brian Ellis | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 229 Durability (JTCP - S&A) | 2025-09-16 | Incomplete | Brian Ellis | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 231 Relative Compaction - Nuclear Gage | 2025-01-17 | Active | Edwin Rojas Flores | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 504 Air Content of PCC - Pressure Method (JTCP - PCC) | 2024-10-26 | Active | Sarbjit Grewal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 518 Unit Weight - PCC (JTCP - PCC) | 2024-10-26 | Active | Sarbjit Grewal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 533 Ball Penetration - PCC | 2025-06-10 | Active | Jay Horton | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 539 Sampling Fresh Concrete (JTCP - PCC) | 2024-10-26 | Active | Sarbjit Grewal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 540 Making Cylinders - PCC (JTCP - PCC) | 2024-10-26 | Active | Sarbjit Grewal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 543 Air Content of PCC - Volumetric Method (JTCP - PCC) | 2024-10-26 | Active | Sarbjit Grewal | Lab 1, Lab 2 | (No comments) |
CT 556 Slump - PCC (JTCP - PCC) | 2024-10-26 | Active | Sarbjit Grewal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 557 Temperature - PCC (JTCP - PCC) | 2024-10-26 | Active | Sarbjit Grewal | Lab 1, Lab 2, Lab 3 | (No comments) |
AASHTO/ASTM Proficiencies
Total 13 items.
Test Method | Expiration Date | Status | IA Responsible | Within Lab(s) Scope | Comments |
---|---|---|---|---|---|
AASHTO T11 Sieve Analysis (Washing) - Fine Aggregates (JTCP - HMA I) | 2022-09-13 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
AASHTO T27 Sieve Analysis - Fine and Coarse Aggregates (JTCP - HMA I) | 2022-09-13 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
AASHTO R47 Reducing Samples of HMA (JTCP - HMA I) | 2022-09-13 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
AASHTO R76 Reducing Samples of Agg (JTCP - HMA I) | 2022-09-13 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
AASHTO T166 Bulk SpG of Compacted HMA - SSD (JTCP - HMA II) | 2022-11-21 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
AASHTO T176 Sand Equivalent (JTCP - HMA I) | 2022-09-13 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
AASHTO T209 Max SpG and Density - HMA (JTCP - HMA II) | 2022-11-21 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
AASHTO T255 Evaporable Moisture Content (JTCP - HMA I) | 2022-09-13 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
AASHTO T269 Percent Air Voids - HMA (JTCP - HMA II) | 2022-11-21 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
AASHTO T275 Bulk SpG - HMA (JTCP - HMA II) | 2022-11-21 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
AASHTO T308 AC Content (Ignition Oven) - HMA (JTCP - HMA II) | 2022-11-21 | Expired | Shaya Meisamifard | Lab 1 | (No comments) |
AASHTO T329 Moisture Content (Oven Method) - HMA (JTCP - HMA I) | 2022-09-13 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
AASHTO T335 Percentage of Fracture (JTCP - HMA I) | 2022-09-13 | Expired | Sarbjit Grewal | Lab 1 | (No comments) |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel