Lab details for Crawford & Associates Inc.

Basic Information

Lab NameCrawford & Associates Inc.
Manager NameChris Trumbull
Lab EmailChris.Trumbull@Crawford-INC.com
Lab Telephone916-380-8762
Lab Fax
Lab Full Address21 West 4th Street , Eureka, CA 95501
Zip95501
Lab TypePrivate
District1
Mobile Lab Full Address, ,
Download TL-0113

RSP Information

21 West 4th Street, Eureka, CA 95501

Test Methods

California Test (CT) Accreditations

Total 27 items.
Test MethodObtained DateExpiration DateStatusIA ResponsibleTechnician Certified?Comments
CT 105: Calculations - Gradings (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 125 AGG: Sampling - AGGREGATES2026-04-022027-04-02ActiveNicholas HallNo
CT 125 AGG: Sampling - AGGREGATES (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 125 GEN: Sampling - GENERAL2026-04-022027-04-02ActiveNicholas HallNo
CT 125 HMA: Sampling - HMA2026-04-022027-04-02ActiveNicholas HallYes
CT 125 HMA: Sampling - HMA (JTCP)2026-04-022027-04-02ActiveNicholas HallNo
CT 201: Sample Preparation - Soil and Aggregates (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 206: SpG & Absorption - Coarse Aggregates2026-04-022027-04-02ActiveNicholas HallNo
CT 207: SpG & Absorption - Fine Aggregates2026-04-022027-04-02ActiveNicholas HallNo
CT 212: Unit Weight of Aggregates2026-04-022027-04-02ActiveNicholas HallNo
CT 216: Relative Compaction - Soils and Aggregates (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 217: Sand Equivalent (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 226: Moisture Content - Soils and Aggregates (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 227: Cleanness Value (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 229: Durability (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 231: Relative Compaction - Nuclear Gage2026-04-022027-04-02ActiveNicholas HallNo
CT 375: AC Density by Nuclear Gage2026-04-022027-04-02ActiveNicholas HallNo
CT 504: Air Content of PCC - Pressure Method (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231)2026-04-022027-04-02ActiveNicholas HallNo
CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 523.2 Section B.3: Flexural Strength (Lab Test)2026-04-022027-04-02ActiveNicholas HallNo
CT 539: Sampling Fresh Concrete (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 540: Making Cylinders - PCC (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 543: Air Content of PCC - Volumetric Method (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 556: Slump - PCC (JTCP)2026-04-022027-04-02ActiveNicholas HallYes
CT 557: Temperature - PCC (JTCP)2026-04-022027-04-02ActiveNicholas HallYes

AASHTO/ASTM Proficiencies

Test MethodObtained DateExpiration DateStatusIA ResponsibleTechnician Certified?Comments
No results found.

Technicians in the Lab

Technician Summary

Total 1 item.
First NameLast NameActions
SpencerChaney View

Technician Details

Details for Spencer Chaney

First NameSpencer
Last NameChaney
StatusActive
Total 23 items.
Certified California Tests(CT)
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
CT 105: Calculations - Gradings (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyYes
CT 125 AGG: Sampling - AGGREGATES (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyYes
CT 125 HMA: Sampling - HMA2023-08-022026-08-02ActiveAlexis EnglandYes
CT 201: Sample Preparation - Soil and Aggregates (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyYes
CT 202: Sieve analysis - Fine and Coarse Aggregates (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyYes
CT 205: Percent Crushed Particles (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyNo
CT 216: Relative Compaction - Soils and Aggregates (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyYes
CT 217: Sand Equivalent (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyYes
CT 226: Moisture Content - Soils and Aggregates (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyYes
CT 227: Cleanness Value (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyYes
CT 229: Durability (JTCP)2025-04-112028-04-11ActiveFirooz Ahmad HosainyYes
CT 231: Relative Compaction - Nuclear Gage2023-08-022025-08-02ExpiredAlexis EnglandYes
CT 375: AC Density by Nuclear Gage2023-08-022025-08-02ExpiredAlexis EnglandYes
CT 504: Air Content of PCC - Pressure Method (JTCP)2022-08-122027-08-12ActiveDalton LaBoskeyYes
CT 518: Unit Weight - PCC (JTCP)2022-08-122027-08-12ActiveDalton LaBoskeyNo
CT 521.2: Compressive Strength - PCC (ASTM C39 / C1231)2023-08-022024-08-02ExpiredAlexis EnglandYes
CT 521.1: Compressive Strength - PCC (ASTM C39 / C617)2023-08-022024-08-02ExpiredAlexis EnglandNo
CT 523.1 Section B.1 & B.2: Flexural Strength (Field Fabrication) (JTCP)2022-08-122027-08-12ActiveDalton LaBoskeyYes
CT 539: Sampling Fresh Concrete (JTCP)2022-08-122027-08-12ActiveDalton LaBoskeyYes
CT 540: Making Cylinders - PCC (JTCP)2022-08-122027-08-12ActiveDalton LaBoskeyYes
CT 543: Air Content of PCC - Volumetric Method (JTCP)2022-08-122027-08-12ActiveDalton LaBoskeyYes
CT 556: Slump - PCC (JTCP)2022-08-122027-08-12ActiveDalton LaBoskeyYes
CT 557: Temperature - PCC (JTCP)2022-08-122027-08-12ActiveDalton LaBoskeyYes
AASHTO/ASTM Proficiencies
Test MethodObtained DateExpiration DateStatusIA ResponsibleWithin Lab Scope?
No results found.