Technician Information for Bryce Trudeau
First Name | Bryce |
---|---|
Last Name | Trudeau |
Technician ID | 01985 |
Associated Labs
Total 3 items.
Lab Name | Manager Name | Full Address | District | Page Alias |
---|---|---|---|---|
G3 Quality, Incorporated - Mobile Laboratory #1 | Matthew Ramos | 25837 Business Center Dr. Suite F, Redlands, CA 92374 | 8 | Lab 1 |
G3 Quality, Incorporated | Matthew Ramos | 13850 Cerritos Corporate Drive, Unit E, Cerritos, CA 90703 | 7 | Lab 2 |
G3 Quality, Incorporated - Redlands Laboratory | Matthew Ramos | 25837 Business Center Drive, Suite F, Redlands, CA 92374 | 8 | Lab 3 |
Test Methods
California Test (CT) Certifications
Total 39 items.
Test Method | Obtained Date | Expiration Date | Status | IA Responsible | Within Lab(s) Scope | Comments |
---|---|---|---|---|---|---|
CT 105 Calculations - Gradings (JTCP - HMA I / S&A) | 2024-10-02 | 2027-10-02 | Active | Sarmad Dalal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 125 ADMIX Sampling - ADMIXTURE | 2022-11-02 | 2024-11-02 | Expired | Rabiul Hyder | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 125 AGG Sampling - AGGREGATES | 2022-11-02 | 2024-11-02 | Expired | Rabiul Hyder | Lab 2, Lab 3 | (No comments) |
CT 125 AGG Sampling - AGGREGATES (JTCP - HMA I / S&A) | 2025-02-21 | 2028-02-21 | Active | Gabriela Lopez | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 125 BIT Sampling - BITUMINOUS | 2022-11-02 | 2024-11-02 | Expired | Rabiul Hyder | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 125 CEM Sampling - CEM | 2022-11-02 | 2024-11-02 | Expired | Rabiul Hyder | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 125 GEN Sampling - GENERAL | 2022-11-02 | 2024-11-02 | Expired | Rabiul Hyder | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 125 HMA Sampling - HMA | 2022-11-02 | 2024-11-02 | Expired | Rabiul Hyder | Lab 2, Lab 3 | (No comments) |
CT 125 HMA Sampling - HMA (JTCP - HMA I) | 2025-02-21 | 2028-02-21 | Active | Gabriela Lopez | Lab 1, Lab 2, Lab 3 | Extend until Dec 14 2018 |
CT 201 Sample Preparation - Soil and Aggregates (JTCP - S&A) | 2024-10-02 | 2027-10-02 | Active | Sarmad Dalal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 202 Sieve analysis - Fine and Coarse Aggregates (JTCP - S&A) | 2024-10-02 | 2027-10-02 | Active | Sarmad Dalal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 204 LL, PL, PI | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2, Lab 3 | (No comments) |
CT 205 Percent Crushed Particles (JTCP - S&A) | 2024-10-02 | 2027-10-02 | Active | Sarmad Dalal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 206 SpG & Absorption - Coarse Aggregates | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 207 SpG & Absorption - Fine Aggregates | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2, Lab 3 | (No comments) |
CT 211 LA Rattler | 2024-10-08 | 2026-10-08 | Active | Shaya Meisamifard | Lab 2, Lab 3 | (No comments) |
CT 216 Relative Compaction - Soils and Aggregates (JTCP - S&A) | 2024-10-02 | 2027-10-02 | Active | Sarmad Dalal | Lab 2, Lab 3 | (No comments) |
CT 217 Sand Equivalent (JTCP - S&A) | 2024-10-02 | 2027-10-02 | Active | Sarmad Dalal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 226 Moisture Content - Soils and Aggregates (JTCP - S&A) | 2024-10-02 | 2027-10-02 | Active | Sarmad Dalal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 227 Cleanness Value (JTCP - S&A) | 2024-10-02 | 2027-10-02 | Active | Sarmad Dalal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 229 Durability (JTCP - S&A) | 2024-10-02 | 2027-10-02 | Active | Sarmad Dalal | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 234 Uncompacted void - Fine Aggregates | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2, Lab 3 | (No comments) |
CT 235 Flat and Elongated Particles | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2, Lab 3 | (No comments) |
CT 301 "R" Value | 2024-02-15 | 2026-02-15 | Active | Roy(Chip) Denner | Lab 3 | (No comments) |
CT 304 Sample Preparation - HMA | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2, Lab 3 | (No comments) |
CT 306 Reducing Samples of Asphalt Mixtures (JTCP - HMA I) | 2025-02-21 | 2028-02-21 | Active | Gabriela Lopez | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 308 Bulk SpG and Density - HMA | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 309 Max SpG and Density - HMA | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 366 Stabilometer | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2, Lab 3 | (No comments) |
CT 370 Moisture Content by Microwave | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 371 Moisture Induced Damage (TSR) | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2 | (No comments) |
CT 382 AC Content by Ignition Oven | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 1, Lab 2, Lab 3 | (No comments) |
CT 384 Combined Grade for HMA using up to 25% RAP | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2, Lab 3 | (No comments) |
CT 389 Hamburg Wheel-Track | 2024-02-15 | 2026-02-15 | Active | Roy(Chip) Denner | Lab 2, Lab 3 | (No comments) |
CT 521.1 Compressive Strength - PCC (ASTM C39 / C617) | 2023-10-20 | 2025-10-20 | Active | Brandt Houchen | Lab 2, Lab 3 | Created based on CT521 certificate ID63267 |
CT 521.2 Compressive Strength - PCC (ASTM C39 / C1231) | 2023-10-20 | 2025-10-20 | Active | Brandt Houchen | Lab 2, Lab 3 | Created based on CT521 certificate ID63267 |
CT 523.1 Section B.1 & B.2 Flexural Strength (Field Fabrication) (JTCP - PCC) | Inactive | Ashley Shaw | Lab 2, Lab 3 | is not ACI Field Technician qualified. Needs to attend ACI and submit a TL-0116. | ||
CT 523.2 Section B.3 Flexural Strength (Lab Test) | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2, Lab 3 | (No comments) |
CT 524 Flexural Strength of Rapid Strength - PCC | 2023-10-20 | 2025-10-20 | Active | Babak Rezaei | Lab 2, Lab 3 | (No comments) |
AASHTO/ASTM Proficiencies
Total 27 items.
JTCP Sessions
Total 1 item.
JTCP Training Code | JTCP Training Start Date | JTCP Training End Date |
---|---|---|
HMA1_LB0088 | 2025-02-18 | 2025-02-21 |
For concerns with missing or erroneous data, please contact your Independent Assurance personnel